     1 -------------------------------
    2 BCM590xx Power Management Units
    3 -------------------------------
    4 
    5 Required properties:
    6 - compatible: "brcm,bcm59056"
    7 - reg: I2C slave address
    8 - interrupts: interrupt for the PMU. Generic interrupt client node bindings
    9   are described in interrupt-controller/interrupts.txt
   10 
   11 ------------------
   12 Voltage Regulators
   13 ------------------
   14 
   15 Optional child nodes:
   16 - regulators: container node for regulators following the generic
   17   regulator binding in regulator/regulator.txt
   18 
   19   The valid regulator node names for BCM59056 are:
   20         rfldo, camldo1, camldo2, simldo1, simldo2, sdldo, sdxldo,
   21         mmcldo1, mmcldo2, audldo, micldo, usbldo, vibldo,
   22         csr, iosr1, iosr2, msr, sdsr1, sdsr2, vsr,
   23         gpldo1, gpldo2, gpldo3, gpldo4, gpldo5, gpldo6,
   24         vbus
   25 
   26 Example:
   27         pmu: bcm59056@8 {
   28                 compatible = "brcm,bcm59056";
   29                 reg = <0x08>;
   30                 interrupts = <GIC_SPI 215 IRQ_TYPE_LEVEL_HIGH>;
   31                 regulators {
   32                         rfldo_reg: rfldo {
   33                                 regulator-min-microvolt = <1200000>;
   34                                 regulator-max-microvolt = <3300000>;
   35                         };
   36 
   37                         ...
   38                 };
   39         };