     1 Lantiq XWAY SoC RCU reset controller binding
    2 ============================================
    3 
    4 This binding describes a reset-controller found on the RCU module on Lantiq
    5 XWAY SoCs.
    6 
    7 This node has to be a sub node of the Lantiq RCU block.
    8 
    9 -------------------------------------------------------------------------------
   10 Required properties:
   11 - compatible            : Should be one of
   12                                 "lantiq,danube-reset"
   13                                 "lantiq,xrx200-reset"
   14 - reg                   : Defines the following sets of registers in the parent
   15                           syscon device
   16                         - Offset of the reset set register
   17                         - Offset of the reset status register
   18 - #reset-cells          : Specifies the number of cells needed to encode the
   19                           reset line, should be 2.
   20                           The first cell takes the reset set bit and the
   21                           second cell takes the status bit.
   22 
   23 -------------------------------------------------------------------------------
   24 Example for the reset-controllers on the xRX200 SoCs:
   25         reset0: reset-controller@10 {
   26                 compatible = "lantiq,xrx200-reset";
   27                 reg <0x10 0x04>, <0x14 0x04>;
   28 
   29                 #reset-cells = <2>;
   30         };