     1 ARM sp804 Dual Timers
    2 ---------------------------------------
    3 
    4 Required properties:
    5 - compatible: Should be "arm,sp804" & "arm,primecell"
    6 - interrupts: Should contain the list of Dual Timer interrupts. This is the
    7         interrupt for timer 1 and timer 2. In the case of a single entry, it is
    8         the combined interrupt or if "arm,sp804-has-irq" is present that
    9         specifies which timer interrupt is connected.
   10 - reg: Should contain location and length for dual timer register.
   11 - clocks: clocks driving the dual timer hardware. This list should be 1 or 3
   12         clocks. With 3 clocks, the order is timer0 clock, timer1 clock,
   13         apb_pclk. A single clock can also be specified if the same clock is
   14         used for all clock inputs.
   15 
   16 Optional properties:
   17 - arm,sp804-has-irq = <#>: In the case of only 1 timer irq line connected, this
   18         specifies if the irq connection is for timer 1 or timer 2. A value of 1
   19         or 2 should be used.
   20 
   21 Example:
   22 
   23         timer0: timer@fc800000 {
   24                 compatible = "arm,sp804", "arm,primecell";
   25                 reg = <0xfc800000 0x1000>;
   26                 interrupts = <0 0 4>, <0 1 4>;
   27                 clocks = <&timclk1 &timclk2 &pclk>;
   28                 clock-names = "timer1", "timer2", "apb_pclk";
   29         };