1 /*-
2 * Copyright (c) 2005 Hans Petter Selasky
3 * All rights reserved.
4 *
5 * Redistribution and use in source and binary forms, with or without
6 * modification, are permitted provided that the following conditions
7 * are met:
8 * 1. Redistributions of source code must retain the above copyright
9 * notice, this list of conditions and the following disclaimer.
10 * 2. Redistributions in binary form must reproduce the above copyright
11 * notice, this list of conditions and the following disclaimer in the
12 * documentation and/or other materials provided with the distribution.
13 *
14 * THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
15 * ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
16 * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
17 * ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
18 * FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
19 * DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
20 * OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
21 * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
22 * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
23 * OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
24 * SUCH DAMAGE.
25 *
26 * $FreeBSD$
27 */
28
29 #ifndef _ACPI_SMBUS_H_
30 #define _ACPI_SMBUS_H_
31
32 /*
33 * System Management Bus register offsets
34 */
35 #define SMBUS_PRTCL 0
36 #define SMBUS_STS 1
37 #define SMBUS_STS_MASK 0x1f
38 #define SMBUS_ADDR 2
39 #define SMBUS_CMD 3
40 #define SMBUS_DATA 4 /* 32 bytes */
41 #define SMBUS_BCNT 36
42 #define SMBUS_ALRM_ADDR 37
43 #define SMBUS_ALRM_DATA 38 /* 2 bytes */
44
45 /*
46 * Smart-Battery commands and definitions
47 */
48
49 /* Base address */
50 #define SMBATT_ADDRESS 0x16
51
52
53 /* access: READ WRITE WORD */
54 #define SMBATT_CMD_MANUFACTURER_ACCESS 0
55
56 /*
57 * access: READ WRITE WORD
58 * unit : mAh (CAPACITY_MODE=0) or 10 mWh (CAPACITY_MODE=1)
59 * range : 0 .. 65535 inclusively
60 */
61 #define SMBATT_CMD_REMAINING_CAPACITY_ALARM 0x1
62
63 /*
64 * access: READ WRITE WORD
65 * unit : minutes
66 * range : 0 .. 65535 inclusively
67 */
68 #define SMBATT_CMD_REMAINING_TIME_ALARM 0x2
69
70 /* access: READ WRITE WORD */
71 #define SMBATT_CMD_BATTERY_MODE 0x3
72
73 #define SMBATT_BM_INTERNAL_CHARGE_CONTROLLER (1 << 0) /* READ */
74 #define SMBATT_BM_PRIMARY_BATTERY_SUPPORT (1 << 1) /* READ */
75 #define SMBATT_BM_CONDITION_FLAG (1 << 7) /* READ */
76 #define SMBATT_BM_CHARGE_CONTROLLER_ENABLED (1 << 8) /* READ WRITE */
77 #define SMBATT_BM_PRIMARY_BATTERY (1 << 9) /* READ WRITE */
78 #define SMBATT_BM_ALARM_MODE (1 << 13) /* READ WRITE */
79 #define SMBATT_BM_CHARGER_MODE (1 << 14) /* READ WRITE */
80 #define SMBATT_BM_CAPACITY_MODE (1 << 15) /* READ WRITE */
81
82 /*
83 * access: READ WRITE WORD
84 * unit : mAh (CAPACITY_MODE=0) or 10 mWh (CAPACITY_MODE=1)
85 * range : signed WORD
86 */
87 #define SMBATT_CMD_AT_RATE 0x4
88
89 /*
90 * access: READ WORD
91 * unit : minutes
92 * range : 0 .. 65534, 65535 has special meaning
93 */
94 #define SMBATT_CMD_AT_RATE_TIME_TO_FULL 0x5
95
96 /*
97 * access: READ WORD
98 * unit : minutes
99 * range : 0 .. 65534, 65535 has special meaning
100 */
101 #define SMBATT_CMD_AT_RATE_TIME_TO_EMPTY 0x6
102
103 /*
104 * access: READ WORD */
105 #define SMBATT_CMD_AT_RATE_OK 0x7
106
107 /*
108 * access: READ WORD
109 * unit : 0.1 degrees Kelvin
110 * range : 0 .. 6553.5 Kelvin
111 */
112 #define SMBATT_CMD_TEMPERATURE 0x8
113
114 /*
115 * access: READ WORD
116 * unit : mV
117 * range : 0 .. 65535 inclusively
118 */
119 #define SMBATT_CMD_VOLTAGE 0x9
120
121 /*
122 * access: READ WORD
123 * unit : mA
124 * range : signed WORD
125 */
126 #define SMBATT_CMD_CURRENT 0xa
127
128 /*
129 * access: READ WORD
130 * unit : mA
131 * range : signed WORD
132 */
133 #define SMBATT_CMD_AVERAGE_CURRENT 0xb
134
135 /*
136 * access: READ WORD
137 * unit : percent
138 * range : 0..100 inclusively
139 */
140 #define SMBATT_CMD_MAX_ERROR 0xc
141
142 /*
143 * access: READ WORD
144 * unit : percent
145 * range : 0..100 inclusively
146 */
147 #define SMBATT_CMD_RELATIVE_STATE_OF_CHARGE 0xd
148
149 /*
150 * access: READ WORD
151 * unit : percent
152 * range : 0..100 inclusively
153 */
154 #define SMBATT_CMD_ABSOLUTE_STATE_OF_CHARGE 0xe
155
156 /*
157 * access: READ WORD
158 * unit : mAh (CAPACITY_MODE=0) or 10 mWh (CAPACITY_MODE=1)
159 * range : 0..65535 inclusively
160 */
161 #define SMBATT_CMD_REMAINING_CAPACITY 0xf
162
163 /*
164 * access: READ WORD
165 * unit : mAh (CAPACITY_MODE=0) or 10 mWh (CAPACITY_MODE=1)
166 * range : 0..65535 inclusively
167 */
168 #define SMBATT_CMD_FULL_CHARGE_CAPACITY 0x10
169
170 /*
171 * access: READ WORD
172 * unit : minutes
173 * range : 0..65534, 65535 is reserved
174 */
175 #define SMBATT_CMD_RUN_TIME_TO_EMPTY 0x11
176
177 /*
178 * access: READ WORD
179 * unit : minutes
180 * range : 0..65534, 65535 is reserved
181 */
182 #define SMBATT_CMD_AVERAGE_TIME_TO_EMPTY 0x12
183
184 /*
185 * access: READ WORD
186 * unit : minutes
187 * range : 0..65534, 65535 is reserved
188 */
189 #define SMBATT_CMD_AVERAGE_TIME_TO_FULL 0x13
190
191 /*
192 * access: READ WORD
193 * unit : mA
194 */
195 #define SMBATT_CMD_CHARGING_CURRENT 0x14
196
197 /*
198 * access: READ WORD
199 * unit : mV
200 * range : 0 .. 65534, 65535 reserved
201 */
202 #define SMBATT_CMD_CHARGING_VOLTAGE 0x15
203
204 /* access: READ WORD */
205 #define SMBATT_CMD_BATTERY_STATUS 0x16
206
207 /* alarm bits */
208 #define SMBATT_BS_OVER_CHARGED_ALARM (1 << 15)
209 #define SMBATT_BS_TERMINATE_CHARGE_ALARM (1 << 14)
210 #define SMBATT_BS_RESERVED_2 (1 << 13)
211 #define SMBATT_BS_OVER_TEMP_ALARM (1 << 12)
212 #define SMBATT_BS_TERMINATE_DISCHARGE_ALARM (1 << 11)
213 #define SMBATT_BS_RESERVED_1 (1 << 10)
214 #define SMBATT_BS_REMAINING_CAPACITY_ALARM (1 << 9)
215 #define SMBATT_BS_REMAINING_TIME_ALARM (1 << 8)
216
217 /* status bits */
218 #define SMBATT_BS_INITIALIZED (1 << 7)
219 #define SMBATT_BS_DISCHARGING (1 << 6)
220 #define SMBATT_BS_FULLY_CHARGED (1 << 5)
221 #define SMBATT_BS_FULLY_DISCHARGED (1 << 4)
222
223 /* error bits */
224 #define SMBATT_BS_GET_ERROR(x) ((x) & 0xf)
225 #define SMBATT_BS_ERROR_OK 0
226 #define SMBATT_BS_ERROR_BUSY 1
227 #define SMBATT_BS_ERROR_RESERVED_COMMAND 2
228 #define SMBATT_BS_ERROR_UNSUPPORTED_COMMAND 3
229 #define SMBATT_BS_ERROR_ACCESS_DENIED 4
230 #define SMBATT_BS_ERROR_OVER_UNDER_FLOW 5
231 #define SMBATT_BS_ERROR_BADSIZE 6
232 #define SMBATT_BS_ERROR_UNKNOWN 7
233
234 /*
235 * access: READ WORD
236 * unit : cycle(s)
237 * range : 0 .. 65534, 65535 reserved
238 */
239 #define SMBATT_CMD_CYCLE_COUNT 0x17
240
241 /*
242 * access: READ WORD
243 * unit : mAh (CAPACITY_MODE=0) or 10 mWh (CAPACITY_MODE=1)
244 * range : 0..65535 inclusively
245 */
246 #define SMBATT_CMD_DESIGN_CAPACITY 0x18
247
248 /*
249 * access: READ WORD
250 * unit : mV
251 * range : 0..65535 mV
252 */
253 #define SMBATT_CMD_DESIGN_VOLTAGE 0x19
254
255 /* access: READ WORD */
256 #define SMBATT_CMD_SPECIFICATION_INFO 0x1a
257
258 #define SMBATT_SI_GET_REVISION(x) (((x) >> 0) & 0xf)
259 #define SMBATT_SI_GET_VERSION(x) (((x) >> 4) & 0xf)
260 #define SMBATT_SI_GET_VSCALE(x) (((x) >> 8) & 0xf)
261 #define SMBATT_SI_GET_IPSCALE(x) (((x) >> 12) & 0xf)
262
263 /* access: READ WORD */
264 #define SMBATT_CMD_MANUFACTURE_DATE 0x1b
265
266 #define SMBATT_MD_GET_DAY(x) (((x) >> 0) & 0x1f)
267 #define SMBATT_MD_GET_MONTH(x) (((x) >> 5) & 0xf)
268 #define SMBATT_MD_GET_YEAR(x) ((((x) >> 9) & 0x7f) + 1980)
269
270 /* access: READ WORD */
271 #define SMBATT_CMD_SERIAL_NUMBER 0x1c
272
273 /* access: READ BLOCK */
274 #define SMBATT_CMD_MANUFACTURER_NAME 0x20
275
276 /* access: READ BLOCK */
277 #define SMBATT_CMD_DEVICE_NAME 0x21
278
279 /* access: READ BLOCK */
280 #define SMBATT_CMD_DEVICE_CHEMISTRY 0x22
281
282 /* access: READ BLOCK */
283 #define SMBATT_CMD_MANUFACTURER_DATA 0x23
284
285 #endif /* !_ACPI_SMBUS_H_ */