FreeBSD/Linux Kernel Cross Reference
sys/dev/puc/puc_cfg.h
1 /*-
2 * SPDX-License-Identifier: BSD-2-Clause-FreeBSD
3 *
4 * Copyright (c) 2006 Marcel Moolenaar
5 * All rights reserved.
6 *
7 * Redistribution and use in source and binary forms, with or without
8 * modification, are permitted provided that the following conditions
9 * are met:
10 *
11 * 1. Redistributions of source code must retain the above copyright
12 * notice, this list of conditions and the following disclaimer.
13 * 2. Redistributions in binary form must reproduce the above copyright
14 * notice, this list of conditions and the following disclaimer in the
15 * documentation and/or other materials provided with the distribution.
16 *
17 * THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
18 * IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
19 * OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
20 * IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
21 * INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
22 * NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
23 * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
24 * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
25 * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
26 * THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
27 *
28 * $FreeBSD$
29 */
30
31 #ifndef _DEV_PUC_CFG_H_
32 #define _DEV_PUC_CFG_H_
33
34 #define DEFAULT_RCLK 1843200
35
36 #define PUC_PORT_NONSTANDARD 0
37 #define PUC_PORT_1P 1 /* 1 parallel port */
38 #define PUC_PORT_1S 2 /* 1 serial port */
39 #define PUC_PORT_1S1P 3 /* 1 serial + 1 parallel ports */
40 #define PUC_PORT_1S2P 4 /* 1 serial + 2 parallel ports */
41 #define PUC_PORT_2P 5 /* 2 parallel ports */
42 #define PUC_PORT_2S 6 /* 2 serial ports */
43 #define PUC_PORT_2S1P 7 /* 2 serial + 1 parallel ports */
44 #define PUC_PORT_3S 8 /* 3 serial ports */
45 #define PUC_PORT_4S 9 /* 4 serial ports */
46 #define PUC_PORT_4S1P 10 /* 4 serial + 1 parallel ports */
47 #define PUC_PORT_6S 11 /* 6 serial ports */
48 #define PUC_PORT_8S 12 /* 8 serial ports */
49 #define PUC_PORT_12S 13 /* 12 serial ports */
50 #define PUC_PORT_16S 14 /* 16 serial ports */
51
52 /* Interrupt Latch Register (ILR) types */
53 #define PUC_ILR_NONE 0
54 #define PUC_ILR_DIGI 1
55 #define PUC_ILR_QUATECH 2
56
57 /* Configuration queries. */
58 enum puc_cfg_cmd {
59 PUC_CFG_GET_CLOCK,
60 PUC_CFG_GET_DESC,
61 PUC_CFG_GET_ILR,
62 PUC_CFG_GET_LEN,
63 PUC_CFG_GET_NPORTS,
64 PUC_CFG_GET_OFS,
65 PUC_CFG_GET_RID,
66 PUC_CFG_GET_TYPE,
67 PUC_CFG_SETUP
68 };
69
70 struct puc_softc;
71
72 typedef int puc_config_f(struct puc_softc *, enum puc_cfg_cmd, int, intptr_t *);
73
74 struct puc_cfg {
75 uint16_t vendor;
76 uint16_t device;
77 uint16_t subvendor;
78 uint16_t subdevice;
79 const char *desc;
80 int clock;
81 int8_t ports;
82 int8_t rid; /* Rid of first port */
83 int8_t d_rid; /* Delta rid of next ports */
84 int8_t d_ofs; /* Delta offset of next ports */
85 puc_config_f *config_function;
86 };
87
88 puc_config_f puc_config;
89
90 #endif /* _DEV_PUC_CFG_H_ */
Cache object: bb8bedbf3a421e260a4c50b63ed87d1d
|